ISPAgents

OPERATOR TOOLS / FIBRE PLANNING

FTTH / GPON optical power budget calculator

Will this split and distance leave enough optical margin? Model one OLT-to-ONT path, compare B+ and C+, and see where the loss goes.

Free. No lead form. Calculations stay in your browser. Calculate now · View results · TR-069 device management

01 / Optics

Use minimum OLT launch power and your ONT datasheet. C+ sensitivity assumes FEC.

02 / Fibre path
03 / Splitter stages

Only include splitters along one OLT → ONT path. Edit loss from the datasheet; count connectors separately.

04 / Connections & reserve

Enter finite numbers within the displayed ranges. No account required; inputs stay in this browser.

Your optical budget

OLT → ONT · 1490 nm · 1:32

ONT Rx grade: Good

Path loss · 1490 nm
21.1 dB
Expected ONT Rx
-19.6 dBm
Remaining margin after reserve
2.9 dB
Loss-limited maximum distance
18.29 km

Safety reserve is met at both 1310 and 1490 nm.

Splitters
16.6 dB
Fibre · 1490 nm
2.5 dB
Connectors + splices
2 dB
Usable optical budget
28 dB
Path loss · 1310 nm
22.1 dB

Margin and distance use the worse of 1310/1490 nm against the G.984.2 class budget for B+/C+. ONT Rx and its grade use 1490 nm only. Verify ONT Tx, OLT sensitivity and upstream penalty separately. Maximum distance excludes ranging and dispersion limits; check equipment reach, commonly 20 km.

Rx grade uses the selected class’s fixed ISPAgents thresholds, even if you edit the receiver limits. The budget check also enforces your receiver limits.

How the budget is calculated

Path loss = fibre length × attenuation + splitter losses + connector pairs × loss per pair + splices × loss per splice. ONT Rx = OLT Tx − path loss at 1490 nm. Safety margin is a reserve, not physical attenuation.

Usable budget = the smaller of the class ceiling and Tx − sensitivity − optical penalty. Remaining margin = usable budget − max(loss at 1310 nm, loss at 1490 nm) − safety reserve. Maximum distance = (usable budget − fixed losses − reserve) / max(attenuation at 1310 nm, attenuation at 1490 nm). Both wavelengths must meet the G.984.2 class loss range. Custom optics use downstream OLT Tx − ONT sensitivity as the budget, with no class ceiling; the same worst-wavelength rule applies. A negative numerator means no feasible distance, even at zero kilometres.

Defaults and sources

ITU-T G.984.2 (08/2019) — Annex A and Appendix V: B+ 13–28 dB, C+ 17–32 dB path-loss windows. Minimum OLT Tx: +1.5 / +3 dBm; ONT sensitivity: −27 / −30 dBm; overload: −8 dBm. Downstream penalty: 0.5 / 1 dB. C+ sensitivity assumes FEC.

Splitter defaults use conservative manufacturer insertion-loss figures, excluding connectors: FS Bare Fiber PLC, p. 4 (1:2 to 1:32) ; FS Mini Plug-in PLC, p. 2 (1:64).

Editable splitter defaults
SplitLoss (dB)
1:23.8
1:47.1
1:810.2
1:1613.5
1:3216.6
1:6421.4

Planning assumptions, not standard guarantees: fibre 0.35 dB/km at 1310 nm and 0.25 at 1490 nm; 0.3 dB per connector pair, 0.1 dB per fusion splice, 3 dB reserve. Replace these with cable and component specifications, including ageing, repair and bend allowances. Splitter loss may vary with wavelength.

Reading the verdict

ISPAgents Rx policy: B+ is good from −24 to −11 dBm, marginal from −27 to below −24 and above −11 to −8, bad outside −27 to −8. C+ shifts the lower hard/good limits to −30/−27 dBm. Endpoints are inclusive. These are Rx grades, not a promise of a working GPON link. Calculated power at or below −40 dBm is bad; the calculator does not measure a no-signal condition.

Does a positive margin guarantee service?

No. Check both directions, receiver overload, minimum class loss, equipment ranging limits, FEC settings and measured end-to-end loss before commissioning.

Can I model two splitter stages?

Yes. For 1:4 followed by 1:8, the overall split is 1:32 but losses add: 7.1 + 10.2 = 17.3 dB before fibre and connections.

From a planned path to device operations

ISPAgents supports TR-069 parameter reads and device management. Validate parameter availability and units for each ONT model. This calculator uses your estimates; it does not connect to an OLT or read live ONT optics.

Explore TR-069 management · Device compatibility guide · Discuss your operator workflow